img

HYZG series Horizontal cylindrical pressure steam sterilizer

Recommended Products
    Product information

    Application

     HYZG Fully Automatic Horizontal Autoclave is widely used in oral department,ophthalmology,operation room and lab and so on.

     HYZG.B Fully Automatic Horizontal Pulse vacuum Autoclave is suitable fro sterilizing unwrapped.wrapped.solid. Hollow A,hollow B,instrument with built-in pipe and implanted instrument which can withstand high temperature and pressure.

     HYZG.N Fully Automatic Horizontal Non-Pulse vacuum Autoclave is suitable for sterilizing unwrapped,wrapped, dressing,rubber,liquid and lab instruments which can withstand high temperature and pressure

    Technical advantage

    1.PLC control,sixty-five thousand color touch screen,powerful and reliable system.

    2.Water injection,pulsing (special for pulse vacuum autoclave),heating up,sterilizing,drying process are fully automatic without artificial regulation

    3.Stage,temperature,pressure,time and fault messages are shown on touch screen display.

    4.Built-in micro-printer,record the whole sterilization information.

    5.Cycle count function

    6.Beep sound once,cycle end and messages shown on screen touch display

    7.HYZG.B Fully Automatic Horizontal Pulse vacuum Autoclave with built-in high quality vacuum pump,1-6 times pulse vacuum can reach -0.09Mpa(-0.9Bar),to ensure effective removal of air of dressing.sterilization bag and hollow instrument so as to get the optimum saturate steam.

    8.Inner circulation structure designed for HYZG.B fully Automatic Horizontal Pulse vacuum Autoclave ,water ring pump without external pipeline,easy to install

    9.Unique pulse vacuum drying procedure designed for HYZG.B fully Automatic Horizontal Pulse vacuum Autoclave,residue moisture is less than 0.2% after drying.

    Safety protection device

    1.Heater protection:the system will cut off its power supply once the temperature exceeds the desired value and show the alarm information

    2.Anti-dry heating:anti-dry heating device will automatically cut off its power supply and show the alarm information once the water level is lower than the heating pipe

    3.Safety interlock door(capacity 80L):Electric lock to ensure the autoclave can begin to work only if the door is closed properly.The door cant be opened when pressure is in chamber or the power supply is not connected

    4.Mechanical pressure interlock door (capacity 120L):the mechanical door device is locked tightly and cant be opened once pressure is in chamber

    5.Over temperature and over-pressure protection:the system will start up procedures to lower temperature and release pressure to protect items from being damaged when the temperature and pressure in chamber exceed the safe limit

    6.Automatic release safety valve:the safety valve will begin to release pressure automatically when the pressure in chamber exceeds the desired value

    7.Electric safety protective measure:short circuit and leakage current are designed to protect equipment and personal safety

     

     

    Main technical parameter

    Design pressure:0.26Mpa

    Design temperature:150

    Max.working pressure:0.23MPa

    Sterilization temperature:0.1

    Temperature homogeneity:≤±0.5

    Sterilization temperature range:105-138

    Water requirement:distilled water

    Chamber material:SUS304 stainless steel

    Model

    Capacity

    Chamber dimensions(Ф×L)

    Outer dimensions(L×W×H)

    Net weight

    Power supply

    Frequency

    Power

    HYZG.B

    50L

    340×580mm

    780×480×1450mm

    160KG

    380V

    50HZ

    7.6KW

    HYZG.B

    60L

    340×680mm

    780×480×1450mm

    175KG

    380V

    50HZ

    7.6KW

    HYZG.B

    80L

    370×755mm

    870×540×1450mm

    185KG

    380V

    50HZ

    7.6KW

    HYZG.B

    120L

    500×665mm

    880×650×1550mm

    252KG

    380V

    50HZ

    10.2KW

    HYZG.B

    140L

    500×765mm

    880×650×1550mm

    275KG

    380V

    50HZ

    10.2KW

    HYZG.B

    160L

    500×865mm

    1080×650×1550mm

    290KG

    380V

    50HZ

    10.5KW

    HYZG.B

    180L

    500×965mm

    1080×650×1550mm

    310KG

    380V

    50HZ

    10.5KW



    Model

    Capacity

    Chamber dimensions(Ф×L)

    Outer dimensions(L×W×H)

    Net weight

    Power supply

    Frequency

    Power

    HYZG.N

    50L

    340×580mm

    780×480×1450mm

    150KG

    220V

    50HZ

    3KW

    HYZG.N

    60L

    340×680mm

    780×480×1450mm

    165KG

    220V

    50HZ

    3KW

    HYZG.N

    80L

    370×755mm

    870×540×1450mm

    180KG

    220V

    50HZ

    4KW

    HYZG.N

    120L

    500×665mm

    880×650×1550mm

    247KG

    380V

    50HZ

    6.7KW

    HYZG.N

    140L

    500×765mm

    880×650×1550mm

    270KG

    380V

    50HZ

    6.7KW

    HYZG.N

    160L

    500×865mm

    1080×650×1550mm

    285KG

    380V

    50HZ

    7.1KW

    HYZG.N

    180L

    500×965mm

    1080×650×1550mm

    305KG

    380V

    50HZ

    7.1KW