HYZ-LX112B High Frequency Mobile Digital C-arm System (5.0 kW, 100mA)
Packing Detail: 2440*1100*1420mm, NW: 440kg GW: 575kg
I. Usage:
Orthopaedics:osteopathy, diaplasis, nailing
Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.
II. Features
1. High quality combined high frequency high voltage xray generator reduces xray dose to body.
2. With function of kV, mA automatically track (ABS) in fluoroscopy to make the image brightness and clearness
3. Real time continuousPulse Fluoroscopy with low dose, but meet operation demand with clearness image
4. Human graphical LCD touch screen, intelligent and fast operation
5. A unique hand-held controller design, convenient to operate
6. Toshiba image intensifier and Medical Mega-pixels digital CCD camera, the quality is stable and reliable, and image clarity
7. Powerful digital graphic workstation with standard configuration of DICOM 3.0 connected to network perfectly, and perfect software
8. Unique design of electric auxiliary support arm is more security for using.
9. New C-arm frame with a compact appearance, and easy to operate
10. Digital radiography with powerful processing program
11. Automatically store the last image of fluoroscopy to advantage diagnosis
III. Configuration
No. |
Item |
Quantity |
1 |
Main frame of C-arm |
1 |
2 |
X-ray generator and high frequency inverted power supply |
1 |
3 |
Toshiba 9’’ image intensifier |
1 |
4 |
Medical Mega-pixels digital CCD camera |
1 |
5 |
Digital Acquisition and Processing workstation |
1 |
6 |
19’’ LCD monitor |
1 |
7 |
14’’high-definitionMedical VGA monitor |
1 |
8 |
Imported minigroove grid |
1 |
9 |
Electric adjustable collimator |
1 |
10 |
Handcontroller |
1 |
11 |
Red light cross localization |
1 |
ⅣPerformance and Parameter
Category |
Item |
Content |
Fluoroscopy/ Photography |
High Frequency Inverter Power Supply |
Output Power:5kW Inverter Frequency:40kHz |
Automatic Fluoroscopy |
Tube Voltage: 40kV~120kV automatic adjustment Tube Current:0.3mA~4mA automatic adjustment |
|
Manual Fluoroscopy |
Tube Voltage:40kV~120kV continuous adjustment Tube Current:0.3mA~4mA continuous adjustment |
|
Pulse Fluoroscopy |
Tube Voltage:40kV~120kV continuous adjustment Tube Current:0.3mA~30mA continuous adjustment 0.1-10 Frame/s |
|
Photography Tube Voltage, mA, mAs |
40 kV-120 kV 25-100mA 1-180 mAs |
|
Plate holder Size |
200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) |
|
X-ray Tube |
X-ray Tube Special for High Frequency |
Fixed anode Dual-focus:0.3/ 1.5mm Anode Thermal Capacity:35kJ |
Video System |
Image Intensifier |
TOSHIBA 9" image intensifier |
CCD Video camera |
Medical Mega-pixels digital CCD camera |
|
Monitor |
14’’high-definitionMedical VGA monitor
Horizontal 1000 lines and vertical 800 lines, |
|
Work Station Software |
Storage without damage, multi-images display, image W/L real time adjustment, grayscale switch, region of interest balance, GAMMA correction, flip, noise reduction, intensifying, smoothing, sharpening, compression, zoom in, measurement, remark, picture-text typeset print, expert template, DICOM image transmit, DICOM image print, cineloop, image imprinting, Worklist registrationetc. |
|
Structural performance |
Directive wheel |
Direction wheel 360°rotation, main wheel ±90°rotation |
C-arm |
ElectricAscending & Descending of pillar movement: 400mm
Forward and Backward Movement: 200mm Slip on orbit: 120°(+90°~ -30°)
|