    1.1 Gantry


    1.1.1 Frame size: 76cm, angle: ±30 degrees, can be remote control operation into / out, rise / fall table and gantry tilt

    1.1.2 Slip ring type: contactless high speed data link slip ring


    1.1.3 Detector type: GOS solid detector


    1.1.4 Detector row: 32





    2.1 X-ray system


    2.1.1 Tube anode heat capacity: 8.0MHU


    2.1.2 Maximum anode heat dissipation rate of tube: 931 KHU/min


    2.1.3 Small focus: 0.6 x 1.2 mm


    2.1.4 Large focus: 1.1 x 1.2 mm


    2.1.5 Focus to the scanning field and other central distance: 570mm


    2.1.6 Minimum tube voltage: 80kV


    2.1.7 Maximum tube voltage: 140kV


    2.1.8 High voltage generator power: 80kW


    2.1.9 Minimum current: 10mA


    2.1.10 Maximum current: 667mA




    2.2 Patient Table


    2.2.1 Maximum scan range: 1850mm


    2.2. The highest vertical movement of the table is 990mm, the lowest vertical movement of the table is 425mm

    2.2.3 Maximum table longitudinal speed: 150 mm/s; minimum longitudinal speed: 5 mm/s

    2.2.4 The table longitudinal movement accuracy: ±0.25 mm


    2.2.5 The maximum patient table load: 250kg




    2.3 Console and computer system


    2.3.1 The main console


    2.3.1.1 Master computer: HP Z820


    2.3.1.2 Computer memory: 32GB


    2.3.1.3 Host hard drive: 7TB


    2.3.1.4 CD-ROM disc recorder system (DICOM compatibility)


    2.3.1.5 Color LCD flat-panel monitors flicker 1 unit (progressive)


    2.3.1.6 Dtandard DICOM3.0 interface: standard configuration, with the following functions:


    Send / receive Query / retrieval Basic print function Storage

    Network interface (RIS / HIS)


    2.3.1.7 Laser camera interface


    2.3.1.8 Remote diagnosis system and remote diagnosis platform


    2.3.1.9 Virtual photo type setting function


    2.3.1.10 Console color 3D display


    2.3.2 Advanced workstation


    2.3.2.1 Offers a package of clinical image processing software, such as MPR, VR, SSD, the maximum and minimum software package Projection; standard configuration volume measurement software.



    2.4 Scan parameters


    2.4.1 Scan time: 0.39s, 0.5s, 0.6s, 0.7s, 0.8s, 1.0s and 2.0 sec


    2.4.2 Imaging speed (number of scan per scan): 64slice/loop


    2.4.3 Scan Slice thickness: 0.625mm, 1.25mm, 2.5mm, 3.75mm, 5mm,


    7.50mm, and 10mm


    2.4.4 Minimum reconstruction display field (FOV): 50mm


    2.4.5 Maximum reconstruction display field (FOV): 500mm


    2.4.6 Image reconstruction matrix: 512 * 512, 1024*1024


    2.4.7 Single scan time: 100 sec


    2.4.8 Maximum scan pitch (Factor Pitch): 1.75:1


    2.4.9 Minimum Factor (Pitch): 0.15:1


    2.4.10 Positioning piece length: 1950 mm




    2.5 Image quality


    2.5.1 Spatial resolution (X, Y axis plane):20 lp/cm 0% MTF


    2.5.2 Spatial resolution (Z axis):20 lp/cm 0% MTF


    2.5.3 Density resolution: (indicating the scan conditions): @0.30% 3mm


    2.5.4 CTDIvol: Head 16.6mGy/100mAs Body; 8.6mGy/100mAs